Custom Adhesive Formulation Tuned to Your Substrate, Climate and Cycle Time

When a standard grade doesn't fit your skin, your oven or your workshop climate, we change the formula, not your line. RELANET adjusts open time, activation temperature, solids, tack and heat limit for automotive interior parts, and supplies under your brand if you need it. Every custom automotive adhesive formulation starts from your substrate, your process and your OEM standard.

Custom automotive adhesive formulation samples
  • 7 days

    Custom samples for difficult substrates, in working days

  • 1–2 months

    Laboratory development to your standard, after we receive your substrates

  • NDA

    Signed before you share materials or process data

  • Free

    Custom samples; you buy production volumes

What We Can Adjust

A tailor-made adhesive for your production line starts from these parameters.

  • Open time

    Why you'd change it
    Time for operators to position skins, or a short open time for fast robotic lines
    Example range today
    R-5670: 8–15 min (hand) / 5–10 min (automated) · R-9610: 45–90 s
  • Activation temperature

    Why you'd change it
    Protect heat-sensitive skins, or tolerate oven drift on automated lines
    Example range today
    R-5670: 65–85°C (hand) / 110–140°C window (automated) · R-5610: above 60°C
  • Solids

    Why you'd change it
    Coat weight, drying time and spray behavior
    Example range today
    R-5670: 47–50% · R-5110 / R-5610: about 50%
  • Initial vs. final tack

    Why you'd change it
    Hold skins on curves straight from the press, or allow repositioning
    Example range today
    R-5670: ~25 N/25 mm at 1 min, ~60 N/25 mm at 7 days
  • Color

    Why you'd change it
    Blue curing agent to see coverage while spraying; colorless for light or visible parts
    Example range today
    R-60C blue or colorless
  • Heat limit

    Why you'd change it
    Sun-exposed parts vs. areas without direct sunlight
    Example range today
    R-7110: 90°C design · R-7206: stable at 110°C
  • Packaging

    Why you'd change it
    Pack size matched to your consumption and handling
    Example range today
    See packaging
Adjustable adhesive parameters
  • Open time

  • Activation temperature

  • Solids

  • Initial vs. final tack

  • Color

  • Heat limit

When a Custom Formula Makes Sense

An adhesive for hard-to-bond substrates, a new process or a new skin usually means a custom formula.

  • Hard-to-bond substrates: low-surface-energy PP, hard TPO, ultra-thin microfiber

    What usually needs to change
    Wetting and adhesion on the substrate; custom samples in 7 working days
  • Cycle time changes

    What usually needs to change
    Open time, activation time and green strength
  • Winter or humid workshops

    What usually needs to change
    Solids, activation temperature, open time
  • New processes: pre-coating, IR activation, robotic dispensing

    What usually needs to change
    Activation behavior and set speed
  • New skins: ultra-thin, ultra-soft, special-touch or light-transmitting skins

    What usually needs to change
    Activation temperature, elongation, optical properties
  • Light-colored or visible parts

    What usually needs to change
    Colorless curing agent, bleed-through control
Blue and clear curing agent for 2K waterborne PU adhesive

Formulas We've Already Tuned

  • Two versions of one 2K waterborne PU

    Result
    Hand-wrapping version (8–15 min open time, 65–85°C activation, 600–1,000% elongation at 10°C) and automated version (5–10 min, 110–140°C window)
    Where
    R-5670
  • A PUR that activates at lower temperature

    Result
    For heat-sensitive thin-wall plastics and soft foams
    Where
    R-9692
  • A high-initial-tack solution for a stressed part

    Result
    Demold force held at the 45 N level; stopped stress debonding on curves and edge returns
    Where
    Honda Ye S7 driver-side wrapped part
  • Curing-agent color

    Result
    Blue for visual coat-weight control; colorless for appearance-critical parts
    Where
    R-60C
  • Climate tuning

    Result
    Solids, activation temperature and open time adjusted on site for South China's humid season and northern winters
    Where
    Customer lines in China
  • A film designed for illuminated trim

    Result
    >99% transmittance, ΔE ≈ 1.0 after 110°C × 1,500 h
    Where
    RY-10, Honda Ye P7 / Ye S7

Formulated for Your Climate

The same adhesive behaves differently in a humid summer in Guangzhou and a winter morning in the north. We adjust the formula for the plant, not just the product.

  • Hot and humid (South China; similar conditions in Brazil and Southeast Asia)

    What happens
    Slow drying, white film after lamination, hydrolysis risk
    What we adjust
    Solids, activation temperature, open time; hydrolysis-resistant chemistry (R-5670: 85% retention after 60°C / 95% RH × 1,000 h)
  • Cold (northern China; Russia and Central Asia)

    What happens
    Longer activation, brittle film, frozen waterborne adhesive
    What we adjust
    Hot melt (APAO / PUR) recommended where frost can't be ruled out; waterborne adhesive only with storage and transport above 5°C; low-temperature elongation (600–1,000% at 10°C)
Adhesive formulated for hot humid and cold climates

What We Need to Start

  • Current adhesive or target grade

    Why
    Starting point for the formula
  • Substrate and skin (materials and suppliers)

    Why
    The material pair decides the bond
  • Part and location in the car

    Why
    Heat, sunlight and stress
  • Application equipment and process

    Why
    Spray, roll, dispense, film; oven and IR settings
  • Target cycle time

    Why
    Open time and set speed
  • Durability and emission standard

    Why
    The OEM tests the formula must pass
  • Volume estimate: annual vehicles × adhesive per vehicle

    Why
    Lets us size the project and plan supply
  • Signed NDA

    Why
    Before you share materials, drawings or process data
  • 1–2 m² of skin and substrate

    Why
    For laboratory development and flat-panel tests

How a Custom Project Runs

Custom formulation workflow
  1. 1

    Step 1: Information review

    What happens
    We review your materials, process and standard
    Time
    —
  2. 2

    Step 2: NDA

    What happens
    Signed by both sides
    Time
    —
  3. 3

    Step 3: Materials received

    What happens
    Your skin and substrate in our lab
    Time
    —
  4. 4

    Step 4: Laboratory development

    What happens
    Formula adjusted and tested to your standard documents
    Time
    1–2 months (custom samples for difficult substrates in 7 working days)
  5. 5

    Step 5: Flat-panel report

    What happens
    Peel, aging and other results against your target
    Time
    —
  6. 6

    Step 6: Trial on your line

    What happens
    Engineers on site; then the eight-step route to SOP

No fixed MOQ: production volumes are agreed per project.

OEM and Private Label Supply

RELANET Formulations Under Your Brand

Building your own adhesive line for automotive interiors? We produce RELANET-qualified formulations under your brand.

  • Your brand

    Detail
    Your label and your product name
  • Your documents

    Detail
    TDS, SDS and COA prepared in your format
  • Confidentiality

    Detail
    Formulation and your process know-how kept confidential under NDA
  • Same quality control

    Detail
    Batch testing, retained samples (about 250 ml per batch) and change control as for our own grades
  • Quality system

    Detail
    IATF 16949 (IATF/T19001-2026), ISO 9001, ISO 14001, ISO 45001
  • Capacity

    Detail
    About 960 t per year

Packaging Built Around Your Line

Pack sizes can be customized to your consumption and handling.

  • PUR hot melt

    Standard format
    20 kg pails
    Notes
    Sealed against moisture; 9-month shelf life at 5–35°C
  • Adhesive film (RY-10)

    Standard format
    Rolls from 1 roll (100 m²)
    Notes
    40–200 µm thickness; die-cut shapes on request
  • Waterborne adhesives

    Standard format
    See TDS
    Notes
    Shipped with frost protection, kept above 5°C
  • Custom

    Standard format
    Sized to your line
    Notes
    Discuss with us

Your Process Stays Yours

  • NDA before data. We sign before you send materials, drawings or process parameters.

  • Your process isn't shared. Customer process details, photos and videos from your line are never published.

  • Our formulas aren't disclosed either. Formulations, raw materials and equipment brands stay confidential, which protects the consistency of what we supply you.

  • Changes are controlled. Once a custom formula is approved, changes follow written change control with advance notice.

Frequently Asked Questions

Custom formulas, including adhesive for hard-to-bond substrates: what we change, how long it takes and how supply works.

  • What can you change in a custom formula?

    Open time, activation temperature, solids, the balance of initial and final tack, curing-agent color, heat limit and packaging.

  • How long does custom development take?

    Custom samples for difficult substrates in 7 working days; laboratory development to your standard in 1–2 months after we receive your materials.

  • Do you sign an NDA?

    Yes, before you share materials or process data.

  • Is there a minimum order for custom formulas?

    No fixed MOQ. Production volumes are agreed per project, based on your annual vehicle volume and adhesive per vehicle.

  • Do custom samples cost anything?

    No. Custom samples are free; production volumes are purchased.

  • Can you supply under our brand?

    Yes. We produce RELANET-qualified formulations under your label and product name, with documents in your format.

  • Can packaging be customized?

    Yes. Pack sizes are matched to your consumption and handling.

Start a Custom Project

Send us your substrate, skin, process, cycle time and OEM standard. We'll sign an NDA, review the project and tell you what can be tuned.

An engineer replies within 1 working day.